(3) Distributed wireless myography

When using the delivery router, connect the computer to the router. Please connect the computer to the router (LAN port) by network cable. Authentication and password may be required for the first connection.

Use medical double-sided tape to stick on the collector and open the collector to make it work. The medical double-sided tape has high viscosity and low viscosity. The high viscosity will leave more glue on the collector, and the low viscosity will leave less glue. When removing residual glue, use an eraser to erase it and wipe it clean with an alcohol cotton. Do not soak the equipment in water or disinfectant, do not use corrosive lotion to clean the equipment;

Open the "EMGx2Server" folder, double-click "EMGx2Server" in the folder (as shown in Figure 189), and wait for the connection of the collector. After the connection is successful, the corresponding collector name will turn from gray to optional state, indicating that the collector has been successfully connected (as shown in Figure 190). Consult technical engineers to obtain the "EMGx2Server" file.

Note that before using "EMGx2Server", please connect to the WiFi of the delivery router on the computer, and do not change the network Settings in the "EMGx2Server" window, just keep the default; Do not start multiple EMGx2Server programs; otherwise, the collector cannot be detected due to port occupation. After connecting to the collector, minimize the programs. After all collectors are connected, select EMG-CH1 for each collector in the second column of Channel Selection (see Figure 191).

Open XINGYING software, open software setting → force table parameter configuration → Channel configuration, check under "on" to configure channels for collectors, pay attention to the number of channels added should be consistent with the number of collectors actually used, close the channel configuration window, and select "Digital myograph" in "Other Configuration".Click the Connect button at the bottom to connect the upper lens and play it. Switch the view type to a simulated chart. Right-click on the chart and select "Edit Page...Click "Show" in the "Visble Channels" window to select all the upper channels, and check "False" on the right side of "AutoScale" at the top and bottom, then you can see the real-time waveform of the collector displayed in the simulation chart, and the maximum and minimum values of each channel will be displayed on the right side of the chart.