(1) Access the force measuring table in AD mode

At present, it supports access to Bertec,AMTI and other force measuring tables through NI6218/6225.

The AD load measuring table needs to use the trigger synchronization of the lens. The digital load measuring table does not use the AD synchronization. It should be noted that the traditional load measuring table and the digital load measuring table cannot be mixed, and only one of them can be configured for use.

After connecting the measuring table to the computer, you need to install the NI driver, and then open the XINGYING software setting, click on the "parameter setting of the measuring table" option, and then click the "+" sign in the "measuring table" module to add the measuring table (as shown in Figure 161);

Click the left mouse button to add the force measuring table, fill in the specifications of the force measuring table, position in space, direction and calibration matrix in the right window, and click "Apply" (Different parameters of the force measuring table are different, please consult the manufacturer/engineer for details...... Then check "Enable force threshold" in the "Noise filter" module and set the value to "5" (Figure 162).

Last updated