(2) Emg data waveform

Do not turn "Wireless" off when connecting digital EMG in the software. Open the Settings, select the option of "digital EMG" in "Other Settings" under the TAB of "Force Table Parameter Settings" (as shown in Figure 186), click channel configuration, right-click the mouse button in the list to add analog channels, and click "on" button to select all the added analog channels (as shown in Figure 187).

Next, connect the lens and play, select the simulation chart in "View Type", right-click "Edit Page" on the chart, click "Show" in the Visble Channels window to check the simulation channel we added above, and check "AutoScale", and attach the special muscle sticker to the muscle belly of the measured muscle.Then, the two ends of the EMG test module are connected with QQ on a special muscle sticker, so that the EMG data and its curve waveform can be displayed in the simulation chart (Figure 188);

You can set the magnification manually by using digital MYG. Open XINGYING Setting → Force table parameter setting → Channel configuration, enter the frame rate multiplier under the channel sampling frequency, and press Enter to make the set multiplier take effect. Sampling frequency = frame rate multiplier × frame rate.